info@tempcontrol.nl | +31 (0) 15 251 18 31

J5 - J series - Ascon Tecnologic

J5 INDICATOR AND TRANSMITTER WITH STRAIN GAUGE INPUT ASCON TECNOLOGIC

Indicator and transmitter with strain gauge input - Ascon Tecnologic
 

  • Panel mount indicator 96 x 48 mm
  • 1 high level or strain gauge input
  • 1 Auxiliary high level input (optional)
  • 1 retransmission output (optional)
  • Automatic calibration routine
  • Tare function for load cells
  • Display of IN1, IN or CIN inclusive of value, peak and valley and hold value
  • RS 485 port with ModBus RTU Protocols (optional)
  • 1 display, 5 digits, h: 15.5 mm, configurable green or red colour

Main features

Process inputs:
1 Main Input IN1
- Voltage (V):  0/1...5 V, 0...10V
- Voltage (mV): 0/10...50 mV
- Current (mA): 0/4...20 mA
- Strain gauge: 350 Ω, with bridge excitation voltage: 5 V or 10 V
- Accuracy : 0.25% ±1 digit (probes) or 0.1% ±1 digit (mA or mV)
- Auxiliary input IN2 (optional)
- Voltage (V):  0/1...5 V, 0...10V
- Current (mA): 0/4...20 mA
- Accuracy : 0.1% ±1 digit: between 85...240 Vac the error is negligible
- Resolution: 16 Bit

3 digital inputs:
- NPN
- TTL
- Free Voltage
Keyboard

Mechanical:
3 multifunction keys + 1 dedicated for alarm acknowledge

Process outputs:
1 High level analogue output:
- Current (mA): 0/4...20 mA

Up to 4 Optional outputs:
OUT1
- RELAY SPDT, 2A/250Vac
OUT2 
- RELAY SPST-NO, 2A (250VAC)
OUT3
- RELAY SPST-NO, 2A (250VAC)
OUT4
- RELAY SPST-NO, 2A (250VAC)

Power supply:
- 24VDC/VAC
- 100… 240 Vac (50/60 Hz)
- Transmitter power supply: 24 Vdc ±20%, 30 mA Max

Functions:
Calculated value (CIN) Selectable between
- IN1 or IN2
- IN1 + IN2
- IN1 – IN2
- IN1 * IN2
- IN1/IN2
- (IN1 + IN2)/2 (average)
- MAX (IN1, IN2) (maximum value)
- Min (IN1, IN2)  (minimum value)

Display indication of:
- Main input IN1
- Auxiliary input IN2
- Calculated Value CIN
- Peak and Valley indication
- Hold and temporized indication
- Automatic calibration routine
- Tare function for load cells

Alarms:
- Up to 4 configurable alarms
- ISA-A Acknowledge function

Communication and programming:
Interfaces
- RS 485 port with ModBus RTU and J-bus (slave) protocols (optional)

Programming/configuration tools:
- Code selection
- Easy to use front interface for configuration
- Configuration software available for PC

Installation:
- Mounting method: panel mount
- Case dimensions: 96 x 48 mm, depth 110 mm (1/8 DIN)

Connections:
- Signals connection
- 36 poles 5.5 mm² screw terminals block
- Protection factor : IP 65 front protection

Display and indicators:
1 display, 5 digits, h: 15.5 mm, configurable green or red colour
4 Alarm and 3 DI LED indicators

Connectable to:
- Any controller from Ascon Tecnologic range with the appropriate I/Os
- SCADA for monitoring, traceability and remote management
- DX and DY gateways for remote monitoring

Ascon Tecnologic

Downloads